Cabinet and General Features
- Enhanced grommets - secure & tight.
- Multi-position available from factory, or field convertible with accessory kit.
- Side return right- or left-hand capable on 12-30, 36 size models.
- All air handlers are basaloid packaged with bar coding and full description on label.
- Filter rack door with thumb screws for easy access and replacement.
- Fiberglass air filter comes with every air handler and filter racks accepts readily available size filters.
- Rigid taupe painted cabinets constructed of heavy gauge steel to prevent corrosion and are lined with high quality
- 5/8" foil faced insulation to prevent sweating.
- UL lab tested 2% or less cabinet air leakage for better efficiency.
- Approved for installation in manufactured housing and mobile homes.
- Lanced fin design and internally enhanced copper tubing.
- Suitable for use with R-22 and R410A.
- Dual 3/4" FPT left and right condensate drain connections.
- Drain pans are molded of corrosion proof high temperature (450a°F) engineering polymer.
- Coils are air pressure tested at 500 PSI, pressure tested with helium, sealed and then charged with dry air.
- Piston, A/C TXV, or HP TXV available factory installed. Screw-on TXVs also available for field installation.
- Suitable for potable water systems.
- Hot water heat kits available both factory and field installed.
- Easy to replace hot water coil. Remove one screw and slide out.
- Optional factory installed circulating pump fully encased in cabinet.
- Optional factory installed 130 degree F Aquastat delays water circulation until hot.
- Purge valve on hot water coil allows for manual release of any air trapped in coil during installation or servicing.
- Water connections 7/8" ODF (for 3/4" water pipe) on 12 - 30, & 36 size models and
- 1 1/8" ODF (for 1" water pipe) on 31, & 37 - 60 size models.
- Variable-speed control board includes dry contacts for thermostat connections.
- Constant air circulation feature runs airflow at 50% of cooling CFM, improves IAQ and eliminates stratification.
- Control board LED Lights display operation mode and when dehumidification is activated.
- Dehumidification - cutting dehumidification resistor on variable-speed control board reduces cooling airflow by 10%.
- Choose your own cooling/heating airflow settings, by selecting taps A-D on the variable-speed control board.
- Fine tune your airflow setting by selecting (+) tap to increase airflow by 10% and (-) tap to decrease airflow by 12%.
- Soft start feature runs airflow at 82% of cooling CFM for first 7.5 minutes of operation.
- Time delay- 1 minute blower off delay at the end of a call for cooling.
- Blower door safety switch on all models.
- Dynamically balanced high efficiency three-speed motors for project flexibility.
- Easy to adjust blower speeds for fine tuning customer comfort.
- Electrical connections can be made on top or both sides of cabinet.
- Electric heat kits available factory installed for 2.5 & 5 Kw. Higher Kw heat kits available for field installation.
- Factory installed fan time delay postpones blower shutoff 30 seconds in heating mode and 45 seconds in cooling mode.