Seller Seller Ratings Info Price Go to Store
www.air-and-heating.com Trusted Seller In Stock New $249 Go to Store
www.airconditionersforhome.com Trusted Seller In Stock New $249 Go to Store
www.mitsubishiductlessairconditionercost.com Trusted Seller In Stock New $249 Go to Store
www.4tonairconditioners.com Trusted Seller In Stock New $249 Go to Store
www.trailerairconditioner.com Trusted Seller In Stock New $249 Go to Store

Note: Your submitted review is subject to the license terms set out in our Terms of Use. By submitting your review, you acknowledge that you have the authority to do so and that your review does not violate another party's copyright or intellectual property rights

Product Details
Name Marvair AVPA24HPA000NU-A2-100 - Wall Mount Heat Pump, Classic, 2 Ton, 208-230/1, No Heat, Manual Damper, Scroll, R410A
Brand Marvair
Item Number AVPA24HPA000NU
Manufacturer Product Number AVPA24HPA000NU-A2-100
SKU - PIM Number 1371469408890
ERP Number 312429
UPC N/A
Unit of Measure EACH
Weight 280.0 Pound (lb.)
Length 16.8 Inches (in)
Width 34.9 Inches (in)
Height 71.2 Inches (in)
Hazardous Material No
EPA Cert Required No
Country of Origin USA
Tier Classic
Equipment Type Heat Pump
SEER 0.0
EER 9.3
CFM 820
Cooling Capacity 24000
Heating Capacity 24000
Voltage 208-230 VAC
Phase Single
Color Black
Energy Star Rated No
Cased Yes
Compressor (1) Scroll
Blower Motor HP 1/5 HP
Condenser Motor HP 1/5 HP
Tonnage 2
Product Family AVPA
GEM - Case Quantity
Classic AVPA
The Classic heat pumps, models AVPA, are built in nominal cooling capacities of 2 to 5 tons (24,000 to 55,000 BTUH's). Each of the units is available with electric resistant heat as second stage or emergency heat. All AVPA series heat pumps use R-410A refrigerant. Scroll compressors are standard on all models. EER's up to 11.1. A complete range of factory installed ventilation options are available including the GreenWheela® ERV. Standard controls include:
  • Defrost control - automatically removes ice or frost on the outdoor coil during cold weather.
  • High refrigerant pressure switch with lockout relay - Turns the unit off to protect the compressor if the refrigerant pressure exceeds the specified set point. A manual reset is required to prevent destructive short cycling.
  • Loss of charge switch with lockout relay - Turns the unit off to protect the compressor if the refrigerant pressure drops below the specified set point. A manual reset is required to prevent harmful short cycling.
Optional Functions & Controls:
  • Dehumidification: Hot gas reheat or electric reheat are offered to control humidity levels in the classroom.
  • Low ambient control - allows unit to operate in the cooling mode when outdoor ambient temperatures are low.
  • Hard start kit - Used on single phase units to compressor higher starting torque when voltage is low. Note: not recommended for use on scroll compressors.
  • Adjustable outdoor thermostat - Will not allow electric resistant heat to be energized unless outdoor temperatures are below a specified set point.
  • "S" circuit - Limits the electric demand by preventing the simultaneous operation of the compressor and the electric heat.
  • Compressor time delay - Prevents the compressor from restarting immediately after an interruption of power. The delay interval is adjustable from 12 seconds to 8 minutes.
  • Many more.
  • Accessories include:
  • Supply grilles
  • Return grilles
  • Return air filter grilles
  • Thermostats